2010 BMW 128i Convertible (E88) L6-3.0L (N52K) Manufacturer Code Page 215

2010 BMW 128i Convertible (E88) L6-3.0L (N52K) Manufacturer Code Page 215

Always

SPORT switch monitor

Sport switch voltages are not plausible and not detected by

diagnosis utility

Terminal condition: Terminal 15 ON

Voltage condition:

Voltage in onboard electrical system >= 10 V

Condition for fault memory entry

480 ms

Action in service

If frequency >=3 Replace DME

Fault effect and breakdown warning

Driver information

Warning light:

MIL OFF EML ON CC: Reduced power, engine

malfunction

RPM limited to 1300 rpm

Service instruction

none

2D59

2D59 – P16C1

Information saved in

DME

Fault code

2D59 – P16C1

Fault text

DME, internal fault: monitoring, actual torque

Fault description

Control Module Self-Test, Torque Monitoring Current

Indicated Value Plausibility

Condition for fault identification

Test condition:

Throttle valve not without current

Driver torque demand is being exceeded

Terminal condition: Terminal 15 ON

Voltage condition:

Voltage in onboard electrical system >= 10 V

Condition for fault memory entry

480 ms

Action in service

Check mass airflow system (vacuum leaks, VVT, VANOS,

throttle valve…)

If frequency is >=3 Replace DME

Fault effect and breakdown warning

Driver information

Warning light:

MIL OFF EML ON CC: Reduced power, engine

malfunction

RPM limited to 1300 rpm