Wednesday, April 29, 2020

2010 BMW 128i Convertible (E88) L6-3.0L (N52K) Manufacturer Code Page 216

2010 BMW 128i Convertible (E88) L6-3.0L (N52K) Manufacturer Code Page 216

2D67 – P0604 (DME)

2D67 – P0604

Information saved in

DME

Fault code

2D67 – P0604

Fault text

DME, internal fault: monitoring, processors

Fault description

Internal Control Module Random Access Memory (RAM)

Error

Condition for fault identification

Test condition:

Internal control-module fault, RAM processor fault

Terminal condition: Terminal 15 ON

Voltage condition:

Voltage in onboard electrical system >= 10 V

Condition for fault memory entry

immediately

Action in service

Ensure that correct softare and data have been flashprogrammed;

repeat flash-programming as indicated. If

frequency > 3 Replace DME

Fault effect and breakdown warning

Driver information

Warning light:

MIL OFF EML ON CC: Power loss, engine malfunction

Service instruction

none

2D67 – P0605 (DME)

2D67 – P0605

Information saved in

DME

Fault code

2D67 – P0605

Fault text

DME, internal fault: monitoring, processors

Fault description

Internal Control Module Read Only Memory (ROM) Error

Condition for fault identification

Test condition:

Internal control-module fault, read memory processor fault

Terminal condition: Terminal 15 ON

Voltage condition:

Voltage in onboard electrical system >= 10 V

Condition for fault memory entry

immediately

Action in service

Ensure that correct softare and data have been flashprogrammed;

repeat flash-programming as indicated. If