2010 BMW 128i Convertible (E88) L6-3.0L (N52K) Manufacturer Code Page 214

2010 BMW 128i Convertible (E88) L6-3.0L (N52K) Manufacturer Code Page 214

Warning light:

MIL OFF EML ON CC: Reduced power, engine

malfunction

RPM limited to 1300 rpm

Service instruction

none

2D58 – P16B9 (DME)

2D58 – P16B9

Information saved in

DME

Fault code

2D58 – P16B9

Fault text

DME, internal fault: monitoring, nominal torque

Fault description

Control Module Self-Test, Torque Loss Monitoring

Condition for fault identification

Test condition:

Control module monitor

Throttle valve not without current

Calculation fault, calculated torque loss too high

Terminal condition: Terminal 15 ON

Voltage condition:

Voltage in onboard electrical system >= 10 V

Condition for fault memory entry

480 ms

Action in service

Check temperature sensors (oil / coolant)

If frequency is >=3 Replace DME

Fault effect and breakdown warning

Driver information

Warning light:

MIL OFF EML ON CC: Reduced power, engine

malfunction

RPM limited to 1300 rpm

Service instruction

none

2D58 – P16C0 (DME)

2D58 – P16C0

Information saved in

DME

Fault code

2D58 – P16C0

Fault text

DME, internal fault: monitoring, nominal torque

Fault description

Control Module Self-Test, Driving Dynamics Control

Switch Monitoring

Condition for fault identification