Wednesday, April 29, 2020

2010 BMW 128i Convertible (E88) L6-3.0L (N52K) Manufacturer Code Page 217

2010 BMW 128i Convertible (E88) L6-3.0L (N52K) Manufacturer Code Page 217

frequency > 3 Replace DME

Fault effect and breakdown warning

Driver information

Warning light:

MIL OFF EML ON CC: Power loss, engine malfunction

Service instruction

none

2D67 – P0606 (DME)

2D67 – P0606

Information saved in

DME

Fault code

2D67 – P0606

Fault text

DME, internal fault: monitoring, processors

Fault description

ECM/PCM Processor

Condition for fault identification

Test condition:

Internal control-module fault, general processor fault

Terminal condition: Terminal 15 ON

Voltage condition:

Voltage in onboard electrical system >= 10 V

Condition for fault memory entry

immediately

Action in service

Ensure that correct softare and data have been flashprogrammed;

repeat flash-programming as indicated. If

frequency > 3 Replace DME

Fault effect and breakdown warning

Driver information

Warning light:

MIL OFF EML ON CC: Power loss, engine malfunction

Service instruction

none

2D67 – P060C (DME)

2D67 – P060C

Information saved in

DME

Fault code

2D67 – P060C

Fault text

DME, internal fault: monitoring, processors

Fault description

Internal Control Module Main Processor Performance

Condition for fault identification