Thursday, April 16, 2020

2010 BMW 128i Convertible (E88) L6-3.0L (N52K) Manufacturer Code Page 113

2010 BMW 128i Convertible (E88) L6-3.0L (N52K) Manufacturer Code Page 113

2CA7 – P0155

Fault text

Oxygen sensor heating before catalytic converter 2, function

Fault description

O2 Sensor Heater Circuit (Bank 2 Sensor 1)

Condition for fault identification

Test condition:

Data content defined

Terminal condition: none

Voltage condition:

none

Condition for fault memory entry

none

Action in service

none

Fault effect and breakdown warning

Driver information

Warning light:

none

Service instruction

none

(DME) Condition For Fault Memory Entry – 1

2CA7 – P0155

Information saved in

DME

Fault code

2CA7 – P0155

Fault text

Oxygen sensor heating before catalytic converter 2, function

Fault description

O2 Sensor Heater Circuit (Bank 2 Sensor 1)

Condition for fault identification

Test condition:

Check O2 sensor heater; sensor too cold

Terminal condition: Terminal 15, engine on

Voltage condition:

none

Condition for fault memory entry

O2 sensor temperature < 680 掳C for more than 5 sec.

Action in service

1. Visual inspection of wires, DME plug and O2 sensor for

damage

2. Check wires (including resistance)

3. Check plug-in connections DME Wiring harness

Upstream (pre-cat) O2 sensor for Bank 2 (water or

corrosion in the plug? => Repeatedly disconnect the plug

and then FIRMLY press it back in)

4. Replace O2 sensor

5. Replace DME

Fault effect and breakdown warning