Thursday, April 16, 2020

2010 BMW 128i Convertible (E88) L6-3.0L (N52K) Manufacturer Code Page 112

2010 BMW 128i Convertible (E88) L6-3.0L (N52K) Manufacturer Code Page 112

1. Visual inspection of wires, DME plug and O2 sensor for

damage

2. Check wires (including resistance)

3. Check plug-in connections DME Wiring harness

Upstream (pre-cat) O2 sensor on Bank 1 (water or

corrosion in the plug? => Repeatedly disconnect the plug

and then FIRMLY press it back in)

4. Replace O2 sensor

5. Replace DME

Fault effect and breakdown warning

Driver information

Warning light:

MIL ON

Service instruction

none

2CA6 – P165F (DME)

2CA6 – P165F

Information saved in

DME

Fault code

2CA6 – P165F

Fault text

Oxygen sensor heating before catalytic converter, function

Fault description

Internal Control Module Measurement Error Oxygen Sensor

Heating (Bank 1, Sensor 1)

Condition for fault identification

Test condition:

Internal control-module fault, attempt to determine O2

sensor temperature failed

No fault memories

Terminal condition: Terminal 15, engine on

Voltage condition:

none

Condition for fault memory entry

Processor chip monitor, no valid temperature for more than

5 sec.

Action in service

Replace DME

Fault effect and breakdown warning

Driver information

Warning light:

none

Service instruction

none

(DME) Condition For Fault Memory Entry – None