Thursday, April 16, 2020

2010 BMW 128i Convertible (E88) L6-3.0L (N52K) Manufacturer Code Page 114

2010 BMW 128i Convertible (E88) L6-3.0L (N52K) Manufacturer Code Page 114

Driver information

Warning light:

MIL ON

Service instruction

none

2CA7 – P166F (DME)

2CA7 – P166F

Information saved in

DME

Fault code

2CA7 – P166F

Fault text

Oxygen sensor heating before catalytic converter 2, function

Fault description

Internal Control Module Measurement Error Oxygen Sensor

Heating (Bank 2, Sensor 1)

Condition for fault identification

Test condition:

Internal control-module fault, attempt to determine O2

sensor temperature failed

No fault memories

Terminal condition: Terminal 15, engine on

Voltage condition:

none

Condition for fault memory entry

Processor chip monitor, no valid temperature for more than

5 sec.

Action in service

Replace DME

Fault effect and breakdown warning

Driver information

Warning light:

none

Service instruction

none

2CA8

2CA8 – P0141

Information saved in

DME

Fault code

2CA8 – P0141

Fault text

Oxygen sensor heating behind catalytic converter, function

Fault description

O2 Sensor Heater Circuit (Bank 1 Sensor 2)

Condition for fault identification

Test condition:

Check internal resistance of O2 sensor to check sensor

heater => If the heater is too weak, the O2 sensor’s internal