2010 BMW 128i Convertible (E88) L6-3.0L (N52K) P Code Charts
none
(DME) Condition For Fault Memory Entry – 2
2AB2 – P0604
Information saved in
DME
Fault code
2AB2 – P0604
Fault text
DME, internal fault: RAM
Fault description
Internal Control Module Random Access Memory (RAM)
Error
Condition for fault identification
Test condition:
RAM checksum test
180
Terminal condition: none
Voltage condition:
none
Condition for fault memory entry
The checksum will be recalculated in response to data
manipulation, leading to a deviation that causes fault code
registration.
Action in service
none
Fault effect and breakdown warning