Friday, June 26, 2020

2010 BMW 128i Convertible (E88) L6-3.0L (N52K) P Code Charts

2010 BMW 128i Convertible (E88) L6-3.0L (N52K) P Code Charts

179

none

(DME) Condition For Fault Memory Entry – 1

2AB2 – P0604

Information saved in

DME

Fault code

2AB2 – P0604

Fault text

DME, internal fault: RAM

Fault description

Internal Control Module Random Access Memory (RAM)

Error

Condition for fault identification

Test condition:

RAM checksum test

This test is executed once, while the control module is

booting.

Terminal condition: Immediately after wakeup in dormant

control module

Voltage condition:

none

Condition for fault memory entry

No debounce. Fault can be reset by clearing fault memory.

Action in service

Determine whether fault is stored again after carrying out

the following procedure. If yes: Replace DME.

1. Clear fault memory

2. Ignition off, allow vehicle to assume complete dormant

status

3. Ignition on

4. Read out stored fault codes from fault memory

Fault effect and breakdown warning