Test condition:

ARS recognized

Terminal condition: Terminal 15 ON

Voltage condition:

Voltage in onboard electrical system > 10 V

Condition for fault memory entry

400 ms

Action in service

Check ARS control module

Fault effect and breakdown warning

Driver information

Warning light:

none

Service instruction

none

CDA4 – U1124 (DME)

CDA4 – U1124

Information saved in

DME

Fault code

CDA4 – U1124

Fault text

Message (status ARS module, 1AC)

Fault description

Lost Communication With ARS-Module Status

Condition for fault identification

Test condition:

ARS recognized

Terminal condition: Terminal 15 ON

Voltage condition:

Voltage in onboard electrical system > 10 V

Condition for fault memory entry

800 ms

Action in service

Check CAN link between ARS and DME

Fault effect and breakdown warning