Friday, May 1, 2020

2010 BMW 128i Convertible (E88) L6-3.0L (N52K) Manufacturer Code Page 239

2010 BMW 128i Convertible (E88) L6-3.0L (N52K) Manufacturer Code Page 239

is defective and must be replaced. Repeat test.

2. If fault code is entered again after QLT replacement: ->

Check wiring harness (BSD_BUS) and all plug-in

connections for corrosion and shorts to ground/UBatt.

3. If fault code no longer appears after QLT replacement: ->

QLT was defective.

4. If no fault code is stored after all components (except

QLT, as in 1.) are disconnected: -> The fault lies with one of

the other BSD_components. Now connect the water pump

and clear all fault memories, ignition off/on.

5. If no fault code is entered now, with the water pumpand

QLT connected -> Connect alternator.

6. If no fault code is stored with water pump, QLT and

alternator connected -> Connect battery sensor.

7. If the system now operates with all BSD components, and

no fault has been detected, recheck the plug connections in

the wiring harness and at the components for good contact /

corrosion.

Fault effect and breakdown warning

Driver information

Warning light:

No oil level display/no oil temperature display available.

Service interval calculations for next visit are based on

model. Water pump runs at 100 % cooling capacity and

draws continuous current of approximately 15A.

Power management fails to operate correctly because it is

not possible to read battery sensor.

Service instruction

none

2E8B – P150A (DME)

2E8B – P150A

Information saved in

DME

Fault code

2E8B – P150A

Fault text

Intelligent battery sensor, signal

Fault description

Battery Sensor BSD (Bit Serial Data Interface) Extended

Communication Circuit

Condition for fault identification

Test condition:

IBS: Interference with extended communications on BSD

bus

Terminal condition: none

Voltage condition:

none

Condition for fault memory entry

10 sec.

Action in service

1. Check BSD wire for sporadic shorts to battery voltage

and ground

2. Check for intermittent contacts

3. Systematically disconnect other BSD components one

after the other and replace as indicated

4. If fault persists after clearing fault memory, replace

battery sensor

5. If fault memory entry is logged repeatedly, replace battery