P1383
2E77 – P1383
Information saved in
DME
Fault code
2E77 – P1383
Fault text
Firing, voltage supply
Fault description
Ignition Monitoring Malfunction
Condition for fault identification
Test condition:
Start process completed, ignition failure on all cylinders
Terminal condition: Terminal 15, engine on
Voltage condition:
6 – 24 V
222
Condition for fault memory entry
Fault is detected when all combustion durations = 0 ms,
Action in service
Check voltage supply and ignition wiring loom including
interfaces
Fault effect and breakdown warning