2010 BMW 128i Convertible (E88) L6-3.0L (N52K) P Code Charts

P1396

29DA – P1396

Information saved in

DME

Fault code

29DA – P1396

Fault text

Crankshaft sensor, segment adaptation

Fault description

Crankshaft Position Sensor Segment Timing Plausibility

Condition for fault identification

Test condition:

In the adaptation phases with active overrun injection

deactivation

Terminal condition: Terminal 15, engine on

Voltage condition:

Voltage in onboard electrical system > 10 V

Condition for fault memory entry

Violation of maximum approved adaptation range

Action in service

Check and replace as indicated: Crankshaft sensor, reluctor

Fault effect and breakdown warning