Wednesday, May 20, 2020

2010 BMW 128i Convertible (E88) L6-3.0L (N52K) Manufacturer Code Page 93

2010 BMW 128i Convertible (E88) L6-3.0L (N52K) Manufacturer Code Page 93

Electrical system voltage Terminal 87 >10.0 V

Condition for fault memory entry

following renewed successful execution of the travel limit

initialization routine

Action in service

1. Use tester request to repeat the VVT travel limit

initialization routine 2. If Item No.1 is not OK, it will be

necessary to check the VVT mechanical components /VVT

servo motor

Fault effect and breakdown warning

Driver information

Warning light:

ECE: No warning message. Engine reverts to VVT

emergency backup mode (throttled operation) US: OPEN

Service instruction

none

2A40

2A40 – P1076

Information saved in

DME

Fault code

2A40 – P1076

Fault text

Valvetronic, thermal overload protection

Fault description

VVT-Overload Protection ECU-Temperature High Input

(Bank 1)

Condition for fault identification

Test condition:

Monitoring of maximum transistor temperature

Terminal condition: Terminal 15 ON

Voltage condition:

none

Condition for fault memory entry

0.03

Action in service

1. Repeat the diagnostic routine once the vehicle cools

2. If Item 1 is not OK, it will be necessary to proceed to an

examination of the control module’s electronic circuitry

Fault effect and breakdown warning

Driver information

Warning light:

Emergency default mode 2