Tuesday, May 12, 2020

2010 BMW 128i Convertible (E88) L6-3.0L (N52K) Manufacturer Code Page 327

2010 BMW 128i Convertible (E88) L6-3.0L (N52K) Manufacturer Code Page 327

Terminal condition: Engine must be running

Voltage condition:

none

Condition for fault memory entry

65 sec. lambda controller + adaptation deviation in max.

1200 sec.

Action in service

– Visual inspection of affected components

– Find and repair leaks

– Mutual exchange of HFM or injector valves

– Inspect HFM plug-in contacts and electrical wires

– Check fuel pressure

Fault effect and breakdown warning

Driver information

Warning light:

MIL on in 2nd driving cycle

Service instruction

none

29E1 – P0175 (DME)

29E1 – P0175

Information saved in

DME

Fault code

29E1 – P0175

Fault text

Mixture control 2

Fault description

System Too Rich (Bank 2)

Condition for fault identification

Test condition:

Closed-loop lambda mixture control = Active

Terminal condition: Engine must be running

Voltage condition:

none

Condition for fault memory entry

75 sec. lambda controller + adaptation deviation in max.

1200 sec.

Action in service

– Visual inspection of affected components

– Reverse mutual installation positions of HFM or injector

valves

– Check HFM plug contacts and electrical wiring

– Check fuel pressure

– Catalyst on one bank melted (visual inspection through O2

sensor fittings)?

Fault effect and breakdown warning

Driver information

Warning light:

MIL on in 2nd driving cycle