Thursday, May 14, 2020

2010 BMW 128i Convertible (E88) L6-3.0L (N52K) Manufacturer Code Page 49

2010 BMW 128i Convertible (E88) L6-3.0L (N52K) Manufacturer Code Page 49

Condition for fault memory entry

Yes, by event counter. Fault must occur ten times before a

fault memory entry is made.

Action in service

Determine whether fault is stored again after carrying out

the following procedure. If yes: Replace DME.

1. Clear fault memory

2. Ignition off, allow vehicle to assume complete dormant

status

3. Ignition on

4. Read out stored fault codes from fault memory

Fault effect and breakdown warning

Driver information

Warning light:

No warning message. No control activation possible from

some DME output terminals.

Service instruction

none

2ACB – P0686 (DME)

2ACB – P0686

Information saved in

DME

Fault code

2ACB – P0686

Fault text

DME master relay, activation

Fault description

ECM/PCM Power Relay Control Circuit Low

Condition for fault identification

Test condition:

Main relay monitoring

Main relay must have opened.

Terminal condition: First Terminal 15 OFF

(wait until main relay opens)

then Terminal 15 ON

(and leave ON)

Voltage condition:

Voltage in onboard electrical system > 10 V

Condition for fault memory entry

none

Action in service

1 Check wiring

Repair if defective

If wiring is OK proceed

to check component

Fault effect and breakdown warning