2010 BMW 128i Convertible (E88) L6-3.0L (N52K) Manufacturer Code Page 209
Fault effect and breakdown warning
Driver information
Warning light:
MIL OFF EML ON CC: Reduced power, engine
malfunction
Reset, rpm limited to 1300 rpm
Service instruction
none
2D55
2D55 – P16B0
Information saved in
DME
Fault code
2D55 – P16B0
Fault text
DME, internal fault: monitoring, accelerator-pedal module
Fault description
Control Module Self-Test, Pedal Position Sensor Monitoring
Condition for fault identification
Test condition:
Control module monitor
Comparison PWG sensor voltage above threshold
Terminal condition: Terminal 15 ON
Voltage condition:
Voltage in onboard electrical system >= 10 V
Condition for fault memory entry
480 ms
Action in service
If frequency >=3 Replace DME
Fault effect and breakdown warning
Driver information
Warning light:
MIL OFF EML ON CC: Reduced power, engine
malfunction
RPM limited to 1300 rpm
Service instruction
none
2D56 – P16B1 (DME)
2D56 – P16B1
Information saved in
DME
Fault code
2D56 – P16B1
Fault text
DME, internal fault: monitoring, idle air control
Fault description
Control Module Self-Test, Idle Air Control System
Integrated Component Plausibility