Thursday, April 16, 2020

2010 BMW 128i Convertible (E88) L6-3.0L (N52K) Manufacturer Code Page 108

2010 BMW 128i Convertible (E88) L6-3.0L (N52K) Manufacturer Code Page 108

2A95 – P0373

Information saved in

DME

Fault code

2A95 – P0373

Fault text

Crankshaft sensor, synchronization

Fault description

Timing Reference High Resolution Signal ‘A’

Intermittent/Erratic Pulses

Condition for fault identification

Test condition:

Engine turns over, camshaft synchronized

Terminal condition: Terminal 15 on

Voltage condition:

none

Condition for fault memory entry

At each synchronization gap if synchronization has been

lost.

Action in service

1. Check signal wire for short to positive, ground, opens and

interference signals

2. Replace crankshaft sensor

Fault effect and breakdown warning

Driver information

Warning light:

MIL 2nd DC

CRK emergency default mode

Service instruction

none

2A96

2A96 – P0370

Information saved in

DME

Fault code

2A96 – P0370

Fault text

Crankshaft sensor, tooth fault

Fault description

Timing Reference High Resolution Signal ‘A’

Condition for fault identification

Test condition:

Engine turns over, camshaft synchronized

Terminal condition: Terminal 15 on

Voltage condition:

none

Condition for fault memory entry

On each synchronization gap, without loss of

synchronization.

Action in service

1. Check signal wire for short to positive, ground, opens and