Friday, July 3, 2020

2010 BMW 128i Convertible (E88) L6-3.0L (N52K) P Code Charts

2010 BMW 128i Convertible (E88) L6-3.0L (N52K) P Code Charts

none

P16A5

2AB6 – P16A5

Information saved in

DME

Fault code

2AB6 – P16A5

Fault text

DME, internal fault: multiple output-stage module

Fault description

Timeout Control Module Multiple Output Stage SPI-Bus

Condition for fault identification

Test condition:

Driver circuit monitor

Terminal condition: Terminal 15 ON

Voltage condition:

none

Condition for fault memory entry

Yes, by event counter. Fault must occur ten times before a

fault memory entry is made.

Action in service

Determine whether fault is stored again after carrying out

the following procedure. If yes: Replace DME.

1. Clear fault memory

2. Ignition off, allow vehicle to assume complete dormant

status

3. Ignition on

4. Read out stored fault codes from fault memory

Fault effect and breakdown warning

Driver information

Warning light:

No warning message. No control activation possible from

some DME output terminals.