2010 BMW 128i Convertible (E88) L6-3.0L (N52K) P Code Charts
none
P16A5
2AB6 – P16A5
Information saved in
DME
Fault code
2AB6 – P16A5
Fault text
DME, internal fault: multiple output-stage module
Fault description
Timeout Control Module Multiple Output Stage SPI-Bus
Condition for fault identification
Test condition:
Driver circuit monitor
Terminal condition: Terminal 15 ON
Voltage condition:
none
Condition for fault memory entry
Yes, by event counter. Fault must occur ten times before a
fault memory entry is made.
Action in service
Determine whether fault is stored again after carrying out
the following procedure. If yes: Replace DME.
1. Clear fault memory
2. Ignition off, allow vehicle to assume complete dormant
status
3. Ignition on
4. Read out stored fault codes from fault memory
Fault effect and breakdown warning
Driver information
Warning light:
No warning message. No control activation possible from
some DME output terminals.