P3223
2E97 – P3223
Information saved in
DME
Fault code
2E97 – P3223
Fault text
Generator
Fault description
Generator Mechanical
Condition for fault identification
Test condition:
Mech. fault
Terminal condition: Terminal 15 ON
Voltage condition:
Voltage in onboard electrical system > 10 V
Condition for fault memory entry
Commercial vehicle >350 rpm,
No communications fault
Action in service
Check bearings, replace belt
Fault effect and breakdown warning