Monday, June 29, 2020

2010 BMW 128i Convertible (E88) L6-3.0L (N52K) P Code Charts

2010 BMW 128i Convertible (E88) L6-3.0L (N52K) P Code Charts

none

(DME) Condition For Fault Memory Entry – 1

2A38 – P1030

Information saved in

DME

Fault code

2A38 – P1030

Fault text

Valvetronic, monitoring, sluggish movement

Fault description

VVT-Actuator Monitoring Position Control, Control

Deviation (Bank 1)

Condition for fault identification

Test condition:

VVT system monitoring for stiction and resistance to

motion.

Always active when no other VVT fault is present.

Terminal condition: Terminal 15 ON

Voltage condition:

Electrical system voltage terminal 87 >10.0 V

Condition for fault memory entry

55 ms

Action in service

1. Use tester to request initialization of travel limits and note

whether travel limit initialization routine executes without

problems. 2. If Item 1 is not OK, replace VVT motor and

repeat Item 1

3. If replacing VVT motor fails to resolve the problem:

Open the valve cover and check the VVT for mechanical

stiction and seizure.

Fault effect and breakdown warning

Driver information

Warning light:

ECE: No warning message. Engine reverts to VVT

emergency backup mode (throttled operation) US: OPEN