2AA9 – P1513 (DME)
2AA9 – P1513
Information saved in
DME
Fault code
2AA9 – P1513
Fault text
Variable intake system, servomotor 2: activation
Fault description
DISA (Differentiated Intake Manifold) Control Circuit
Signal High
Condition for fault identification
Test condition:
Monitoring of DISA controller 2 actuator
Engine speed > 500 rpm
Terminal condition: Terminal 15, engine on
Voltage condition:
Voltage in onboard electrical system > 10 V
Condition for fault memory entry
none
Action in service
1 Check wiring
Repair if defective
If wiring is OK proceed
to check component