Fault description

Evaporative Emission System Switching Valve Control

Circuit Low

Condition for fault identification

Test condition:

Monitoring of control activation

when solenoid is triggered

Terminal condition: Terminal 15 ON

Voltage condition:

Voltage in onboard electrical system > 10 V

Condition for fault memory entry

0.5 sec.

Action in service

1Check wiring

Repair if defective

If wiring is OK proceed

to check component

Fault effect and breakdown warning

Driver information

Warning light:

MIL ON

Service instruction

none

2A12 – P2420 (DME)

2A12 – P2420

Information saved in

DME

Fault code

2A12 – P2420

Fault text

DMTL solenoid valve, activation

Fault description

Evaporative Emission System Switching Valve Control

Circuit High

Condition for fault identification

Test condition:

Monitoring of control activation

when solenoid is triggered

Terminal condition: Terminal 15 ON

Voltage condition:

Voltage in onboard electrical system > 10 V

Condition for fault memory entry

0.5 sec.

Action in service

1Check wiring

Repair if defective

If wiring is OK proceed

to check component

Fault effect and breakdown warning