P2088
2A80 – P2088
Information saved in
DME
Fault code
2A80 – P2088
Fault text
Intake VANOS, activation
Fault description
‘A’ Camshaft Position Actuator Control Circuit Low (Bank
1)
Condition for fault identification
Test condition:
Monitoring of VANOS control
Engine speed > 500 rpm
Terminal condition: Terminal 15, engine on
Voltage condition:
Voltage in onboard electrical system > 10 V
Condition for fault memory entry
none
Action in service
1Check wiring
Repair if defective
If wiring is OK proceed
to check component
Fault effect and breakdown warning