Tuesday, May 26, 2020

2010 BMW 128i Convertible (E88) L6-3.0L (N52K) P Code Charts

P1625

2D1E – P1625

245

Information saved in

DME

Fault code

2D1E – P1625

Fault text

Accelerator-pedal module, pedal-position sensor 2, voltage

supply

Fault description

Pedal Position Sensor Potentiometer Supply Channel 2

Electrical

Condition for fault identification

Test condition:

Pedal-position sensor monitor

Terminal condition: Terminal 15 ON

Voltage condition:

Voltage in onboard electrical system >= 10 V

Condition for fault memory entry

0.02 sec.

Action in service

1) Check fault memory for problem with throttle valve

and/or main relay, replace main relay as indicated

2) Check power-supply wire for short to ground (also

measure in PWG),

3) Replace DME

Fault effect and breakdown warning

Driver information

Warning light:

CC status report: Reduced engine power!

EML ON restricted PW gradient and PW limit via rpm