2010 BMW 128i Convertible (E88) L6-3.0L (N52K) Manufacturer Code Page 31
Warning light:
MIL ON
Service instruction
none
CD99 – U110E (DME)
CD99 – U110E
Information saved in
DME
Fault code
CD99 – U110E
Fault text
Message (torque request EGS, B5)
Fault description
Message Monitoring Torque Request ETC Alive Check
Condition for fault identification
Test condition:
EGS detected
Terminal condition: Terminal 15 ON
Voltage condition:
Voltage in onboard electrical system > 10 V
Condition for fault memory entry
200 ms
Action in service
Check EGS and replace as indicated (fault in EGS control
module)
Fault effect and breakdown warning
Driver information
Warning light:
MIL ON
Service instruction
none
CD99 – U110F (DME)
CD99 – U110F
Information saved in
DME
Fault code
CD99 – U110F
Fault text
Message (torque request EGS, B5)
Fault description
Lost Communication With Torque Request ETC
Condition for fault identification
Test condition:
EGS detected
Terminal condition: Terminal 15 ON
Voltage condition:
Voltage in onboard electrical system > 10 V
Condition for fault memory entry