Sunday, May 10, 2020

2010 BMW 128i Convertible (E88) L6-3.0L (N52K) Manufacturer Code Page 310

2010 BMW 128i Convertible (E88) L6-3.0L (N52K) Manufacturer Code Page 310

Test condition:

PLAUS

Terminal condition: no invariable debounce time, constant

sensor data reading during engine warm-up produces entry

Voltage condition:

Terminal 15 ON

Condition for fault memory entry

Plausibility monitoring of ambient temperature sensor with

end of start phase recognized

Action in service

Constant, invariable sensor signal:

Sticking sensor, sensor manipulation

Fault effect and breakdown warning

Driver information

Warning light:

1) Visual inspection of sensor

2) Electrical check on sensor wire and power supply wire

2) Check sensor data response to motion

3) Replace sensor

Service instruction

none

Condition For Fault Memory Entry – at Least 2 Bits Are Set to 2

29CC – P0300

Information saved in

DME

Fault code

29CC – P0300

Fault text

Combustion misfires, several cylinders

Fault description

Random/Multiple Cylinder Misfire Detected

Condition for fault identification

Test condition:

Combustion consistency measurement. Starting at engine

speed n > 450 and n 740 hPa

Combustion miss on at least two cylinders

Terminal condition: Terminal 15, engine on

Voltage condition:

Voltage in onboard electrical system > 10 V

Condition for fault memory entry

at least 2 bits from Sym0 are set to 2

Action in service

Ignition coils, spark plugs, ignition cables, injectors, DME

Fault effect and breakdown warning

Driver information

Warning light:

MIL ON

Service instruction

none

Condition For Fault Memory Entry – Miss Within First 1000 Crankshaft Rotations