Monday, May 18, 2020

2010 BMW 128i Convertible (E88) L6-3.0L (N52K) Manufacturer Code Page 76

2010 BMW 128i Convertible (E88) L6-3.0L (N52K) Manufacturer Code Page 76

Voltage condition:

Voltage in onboard electrical system > 10 V

Condition for fault memory entry

0.5 sec.

Action in service

1Check wiring

Repair if defective

If wiring is OK proceed

to check component

Fault effect and breakdown warning

Driver information

Warning light:

MIL ON

Service instruction

none

2A13 – P2402 (DME)

2A13 – P2402

Information saved in

DME

Fault code

2A13 – P2402

Fault text

DMTL leak diagnosis pump, activation

Fault description

Evaporative Emission System Leak Detection Pump Control

Circuit High

Condition for fault identification

Test condition:

Monitoring of control activation

when pump is triggered

Terminal condition: Terminal 15 ON

Voltage condition:

Voltage in onboard electrical system > 10 V

Condition for fault memory entry

0.5 sec.

Action in service

1Check wiring

Repair if defective

If wiring is OK proceed

to check component

Fault effect and breakdown warning