P1675
2CFD – P1675
Information saved in
DME
Fault code
2CFD – P1675
Fault text
No throttle-valve adaptation value
Fault description
Throttle Valve Actuator Start Test Re-Adaptation Required
Condition for fault identification
Test condition:
Switch terminals
Terminal condition: Terminal 15 ON
Voltage condition:
Voltage in onboard electrical system >= 10 V
Condition for fault memory entry
1 sec.
Action in service
254
1) Note collateral issues related to initial adaptation,
2) Check: The sum of throttle valve voltages must equal 5
V,
3) Perform electrical check on wiring to throttle valve
sensors and throttle valve motor, visual inspection of plug-in
contacts (at component, wiring harness and DME),
4) Replace component
Fault effect and breakdown warning
Driver information
Warning light:
CC status report: Reduced engine performance!,
MIL ON
EMB + rpm limit 1300 rpm