Thursday, April 23, 2020

2010 BMW 128i Convertible (E88) L6-3.0L (N52K) Manufacturer Code Page 165

2010 BMW 128i Convertible (E88) L6-3.0L (N52K) Manufacturer Code Page 165

Fault text

DME, internal fault: oxygen sensor

Fault description

O2 Sensor Initialization Error WRAF-IC (Bank 1 Sensor 1)

Condition for fault identification

Test condition:

Monitoring of O2 sensor chip

No fault memories

Terminal condition: Terminal 15 ON

Voltage condition:

none

Condition for fault memory entry

Self-diagnosis processor chip: Communications fault with

绀?
Action in service

Replace DME

Fault effect and breakdown warning

Driver information

Warning light:

MIL ON

Service instruction

none

2C42 – P3023 (DME)

2C42 – P3023

Information saved in

DME

Fault code

2C42 – P3023

Fault text

DME, internal fault: oxygen sensor 2

Fault description

O2 Sensor Disturbed SPI Communication to WRAF-IC

(Bank 2 Sensor 1)

Condition for fault identification

Test condition:

Monitoring of O2 sensor chip

No fault memories

Terminal condition: Terminal 15 ON

Voltage condition:

none

Condition for fault memory entry

Self-diagnosis processor chip: Communications fault with

绀?
Action in service

Replace DME

Fault effect and breakdown warning