Monday, April 27, 2020

2010 BMW 128i Convertible (E88) L6-3.0L (N52K) Manufacturer Code Page 201

2010 BMW 128i Convertible (E88) L6-3.0L (N52K) Manufacturer Code Page 201

Fault text

Air-mass sensor, signal

Fault description

Air Mass Flow Sensor Defective

Condition for fault identification

Test condition:

Engine start completed

Terminal condition: Terminal 15

Voltage condition:

OBD1 conditions met (voltage between 10 V and 16 V)

Condition for fault memory entry

0.2 sec.

Action in service

1) Visual inspection of plug-in contacts (at both component

and DME ends)

2) Measure sensor wire, power supply and ground (possible

intermittent contact!)

3) Replace sensor

Fault effect and breakdown warning

Driver information

Warning light:

none

Service instruction

none

2D20

2D20 – P2138

Information saved in

DME

Fault code

2D20 – P2138

Fault text

Accelerator-pedal module, pedal-position sensor,

plausibility between signal 1 and signal 2

Fault description

Throttle/Pedal Position Sensor/Switch ‘D’ / ‘E’ Voltage

Correlation

Condition for fault identification

Test condition:

Pedal-position sensor monitor

Terminal condition: Terminal 15 ON

Voltage condition:

Voltage in onboard electrical system >= 10 V

Condition for fault memory entry

0.02 sec.

Action in service

1) Check: Pedal-position sensor voltages [Pot voltage 2 =

(Pot voltage1)/2]2)

Check wires from DME to PWG,

3) Visual inspection of plug terminals (on components,

wiring harness and DME),

4) Replace PWG

Fault effect and breakdown warning