Monday, April 27, 2020

2010 BMW 128i Convertible (E88) L6-3.0L (N52K) Manufacturer Code Page 200

2010 BMW 128i Convertible (E88) L6-3.0L (N52K) Manufacturer Code Page 200

Condition for fault memory entry

0.2 sec.

Action in service

1) Check frequency of HFM

2) Check sensor and replace as indicated

Fault effect and breakdown warning

Driver information

Warning light:

none

Service instruction

none

2D16 – P0100 (DME)

2D16 – P0100

Information saved in

DME

Fault code

2D16 – P0100

Fault text

Air-mass sensor, signal

Fault description

Mass or Volume Air Flow ‘A’ Circuit

Condition for fault identification

Test condition:

Engine start completed

Terminal condition: Terminal 15

Voltage condition:

OBD1 conditions met (voltage between 10 V and 16 V)

Condition for fault memory entry

0.2 sec.

Action in service

1) Visual inspection of plug-in terminals (at components and

DME)

2) Perform electrical check on sensor wire, power supply

and ground

3) Replace sensor

Fault effect and breakdown warning