2010 BMW 128i Convertible (E88) L6-3.0L (N52K) Manufacturer Code Page 221
Condition for fault identification
Test condition:
Commercial vehicle > 350 rpm, no BSD communications
fault
Terminal condition: Terminal 15 ON, no BSD fault
Voltage condition:
none
Condition for fault memory entry
25 sec.
Action in service
Inspect alternator for unobstructed air current.
Fault effect and breakdown warning
Driver information
Warning light:
none
Service instruction
none
2ED0
2ED0 – P324C
Information saved in
DME
Fault code
2ED0 – P324C
Fault text
Generator, plausibility: temperature
Fault description
Generator Over Temperature Calculated
Condition for fault identification
Test condition:
Diagnosis not active, specific to application
Terminal condition: Terminal 15 ON, no BSD fault
Voltage condition:
none
Condition for fault memory entry
Never, diagnosis not active
Action in service
Inspect alternator for unobstructed air current.
Fault effect and breakdown warning