Tuesday, April 28, 2020

2010 BMW 128i Convertible (E88) L6-3.0L (N52K) Manufacturer Code Page 211

2010 BMW 128i Convertible (E88) L6-3.0L (N52K) Manufacturer Code Page 211

Service instruction

none

2D57 – P16B3 (DME)

2D57 – P16B3

Information saved in

DME

Fault code

2D57 – P16B3

Fault text

DME, internal fault: monitoring, external torque request

Fault description

Control Module Self-Test, MSR (Engine-Drag-Torque

Control) Monitoring

Condition for fault identification

Test condition:

Control module monitor

Throttle valve not without current

Interface fails to detect implausible torque demand

Terminal condition: Terminal 15 ON

Voltage condition:

Voltage in onboard electrical system >= 10 V

Condition for fault memory entry

480 ms

Action in service

Check CAN, MSR control module

If frequency is >= 3 Replace DME

Fault effect and breakdown warning

Driver information

Warning light:

MIL OFF EML OFF CC: ???

DSC cancelled

Service instruction

none

2D57 – P16B5 (DME)

2D57 – P16B5

Information saved in

DME

Fault code

2D57 – P16B5

Fault text

DME, internal fault: monitoring, external torque request

Fault description

Control Module Self-Test, AMT (Automatic Manual

Transmission) Monitoring

Condition for fault identification

Test condition:

Control module monitor

Interface fails to detect implausible torque demand

Terminal condition: Terminal 15 ON