Monday, April 13, 2020

2010-2020 BMW 128i Diagnostic and Repair Information

2F11 – U1130 (DME)

2F11 – U1130

Information saved in

DME

Fault code

2F11 – U1130

Fault text

Radiator blind, top

Fault description

Lost Communication With Radiator Shutter (Upper)

Condition for fault identification

Test condition:

1. AKKS must be initalized.

Operation of lower flap:

3 x open and 3 x closed

Or conduct the system test

Terminal condition: Terminal 15 ON

Voltage condition:

Voltage in onboard electrical system > 10 V

Condition for fault memory entry

none

Action in service

1. Check voltage supply to AKKS (focus especially on GND

[PIN 2] at the valve)

2. If OK, then replace AKKS

Fault effect and breakdown warning