Condition For Fault Memory Entry – Miss Within First 1000 Crankshaft Rotations
29D2 – P0306
Information saved in
DME
Fault code
29D2 – P0306
Fault text
Combustion misfires, cylinder 6
Fault description
Cylinder 6 Misfire Detected
Condition for fault identification
Test condition:
Combustion consistency measurement. Starting at engine
speed n > 450 and n < 7000. Ambient pressure > 740 hPa
Terminal condition: Terminal 15, engine on
Voltage condition:
Voltage in onboard electrical system > 10 V
Condition for fault memory entry
Combustion miss within first 1000 crankshaft rotations after
start
Action in service
Ignition coils, spark plugs, ignition cables, injectors, DME
Fault effect and breakdown warning