Monday, April 13, 2020

2010-2020 BMW 128i Diagnostic and Repair Information

2F11 – P14C4 (DME)

2F11 – P14C4

Information saved in

DME

Fault code

2F11 – P14C4

Fault text

Radiator blind, top

Fault description

Radiator Shutter (Upper) Mechanical

Condition for fault identification

Test condition:

1. AKKS must be initalized.

Operation of lower flap:

3 x open and 3 x closed

Or conduct the system test

Terminal condition: Terminal 15 ON

Voltage condition:

Voltage in onboard electrical system > 10 V

Condition for fault memory entry

none

Action in service

1. Check AKKS for sticking and seizure. (may be iced up in

winter)

2. Use the tester to trigger the valve repeatedly.

If OK Clear fault memory, conduct system test –> No fault

code entry

If not OK: Replace AKKS and conduct test for GLF –> No

fault code entry

Fault effect and breakdown warning