2F58
2F58 – P0512
Information saved in
DME
Fault code
2F58 – P0512
Fault text
Automatic starting, activation
Fault description
Starter Request Circuit
Condition for fault identification
Test condition:
Automatic starter activation-control monitor
Convenience start relay initialized
Start relay installed
Terminal condition: Terminal 15 ON
Voltage condition:
Voltage in onboard electrical system > 10 V
Condition for fault memory entry
1 sec.
Action in service
Check wiring
Repair if defective
If wiring is OK proceed
to check component (start relay)
Fault effect and breakdown warning
2010-2020 BMW 128i Convertible (E88) L6-3.0L (N51) WWW.168MOTIVE.COM Page 299