2A3F – P1056 (DME)

2A3F – P1056

Information saved in

DME

Fault code

2A3F – P1056

Fault text

Valvetronic, actuator motor: power supply

Fault description

VVT-Supply Voltage Control Motor Low Input (Bank 1)

Condition for fault identification

Test condition:

VVT servo motor power supply monitor

Terminal condition: Terminal 15 ON

Voltage condition:

Electrical system voltage terminal 87 >10.0 V

Condition for fault memory entry

Power supply voltage < 5.75VAction in service1. Check VVT power supply voltage with multimeter.Supply voltage must lie between 5.75V and 17V.2. If result is outside specified range: Inspect the powersupplywire to the VVT pins and check the plug.3. If contact is stretched or corroded: Replace plug 4. Ifwiring harness is defective: Replace wiring harness.Fault effect and breakdown warning