Showing posts with label (DME) Condition For Fault Memory Entry - None. Show all posts
Showing posts with label (DME) Condition For Fault Memory Entry - None. Show all posts

Thursday, July 23, 2020

2010 BMW 128i Convertible (E88) L6-3.0L (N52K) P Code Charts

2010 BMW 128i Convertible (E88) L6-3.0L (N52K) P Code Charts

none

(DME) Condition For Fault Memory Entry – None

2C3E – P112D

Information saved in

DME

Fault code

2C3E – P112D

Fault text

Oxygen sensor before catalytic converter 2, line fault

Fault description

O2 Sensor Negative Current or Positive Current Control

Circuit/Open (Bank 2 Sensor 1)

Condition for fault identification

Test condition:

Not supported

Terminal condition: none

Voltage condition:

none

Condition for fault memory entry

none

Action in service

none

61

Fault effect and breakdown warning

Wednesday, July 22, 2020

2010 BMW 128i Convertible (E88) L6-3.0L (N52K) P Code Charts

2010 BMW 128i Convertible (E88) L6-3.0L (N52K) P Code Charts

none

(DME) Condition For Fault Memory Entry – None

2C3D – P112C

Information saved in

DME

Fault code

2C3D – P112C

Fault text

Oxygen sensor before catalytic converter, line fault

Fault description

O2 Sensor Negative Current or Positive Current Control

Circuit/Open (Bank 1 Sensor 1)

Condition for fault identification

Test condition:

Not supported

Terminal condition: none

Voltage condition:

none

Condition for fault memory entry

none

Action in service

none

Fault effect and breakdown warning

Tuesday, July 21, 2020

2010 BMW 128i Convertible (E88) L6-3.0L (N52K) P Code Charts

2010 BMW 128i Convertible (E88) L6-3.0L (N52K) P Code Charts

none

(DME) Condition For Fault Memory Entry – None

49

2A46 – P101A

Information saved in

DME

Fault code

2A46 – P101A

Fault text

Valvetronic, adaptation

Fault description

VVT-Self-Learning Function, Stops Not Learned

Condition for fault identification

Test condition:

none

Terminal condition: none

Voltage condition:

none

Condition for fault memory entry

none

Action in service

none

Fault effect and breakdown warning

Monday, June 29, 2020

2010 BMW 128i Convertible (E88) L6-3.0L (N52K) P Code Charts

2010 BMW 128i Convertible (E88) L6-3.0L (N52K) P Code Charts

none

(DME) Condition For Fault Memory Entry – None

2A38 – P1030

Information saved in

DME

Fault code

2A38 – P1030

Fault text

Valvetronic, monitoring, sluggish movement

Fault description

VVT-Actuator Monitoring Position Control, Control

Deviation (Bank 1)

Condition for fault identification

Test condition:

none

Terminal condition: none

Voltage condition:

none

Condition for fault memory entry

none

Action in service

none

Fault effect and breakdown warning

Monday, June 8, 2020

2010 BMW 128i Convertible (E88) L6-3.0L (N52K) P Code Charts

2010 BMW 128i Convertible (E88) L6-3.0L (N52K) P Code Charts

none

(DME) Condition For Fault Memory Entry – None

2CA7 – P0155

Information saved in

DME

Fault code

2CA7 – P0155

Fault text

Oxygen sensor heating before catalytic converter 2, function

Fault description

O2 Sensor Heater Circuit (Bank 2 Sensor 1)

Condition for fault identification

Test condition:

Data content defined

Terminal condition: none

Voltage condition:

none

Condition for fault memory entry

none

Action in service

none

Fault effect and breakdown warning

Saturday, June 6, 2020

2010 BMW 128i Convertible (E88) L6-3.0L (N52K) P Code Charts

2010 BMW 128i Convertible (E88) L6-3.0L (N52K) P Code Charts

none

(DME) Condition For Fault Memory Entry – None

2CA6 – P0135

Information saved in

DME

Fault code

2CA6 – P0135

Fault text

Oxygen sensor heating before catalytic converter, function

Fault description

O2 Sensor Heater Circuit (Bank 1 Sensor 1)

Condition for fault identification

Test condition:

Data content defined

Terminal condition: none

Voltage condition:

none

Condition for fault memory entry

none

Action in service

none

Fault effect and breakdown warning

Monday, April 13, 2020

2010-2020 BMW 128i Diagnostic and Repair Information

(DME) Condition For Fault Memory Entry – None

2A38 – P1030

Information saved in

DME

Fault code

2A38 – P1030

Fault text

Valvetronic, monitoring, sluggish movement

Fault description

VVT-Actuator Monitoring Position Control, Control

Deviation (Bank 1)

Condition for fault identification

Test condition:

none

Terminal condition: none

Voltage condition:

none

Condition for fault memory entry

none

Action in service

none

Fault effect and breakdown warning