Wednesday, July 15, 2020

2010 BMW 128i Convertible (E88) L6-3.0L (N52K) P Code Charts

2010 BMW 128i Convertible (E88) L6-3.0L (N52K) P Code Charts

none

P16B6

2D57 – P16B6

Information saved in

DME

Fault code

2D57 – P16B6

Fault text

DME, internal fault: monitoring, external torque request

Fault description

Control Module Self-Test, ETC Monitoring

Condition for fault identification

Test condition:

Control module monitor

Interface fails to detect implausible torque demand

Terminal condition: Terminal 15 ON

Voltage condition:

Voltage in onboard electrical system >= 10 V

Condition for fault memory entry

480 ms

Action in service

Check CAN, EGS control module

If frequency is >=3 Replace DME

Fault effect and breakdown warning

Driver information

Warning light:

MIL OFF EML OFF CC: ???