2010 BMW 128i Convertible (E88) L6-3.0L (N52K) P Code Charts
none
P060C
2D67 – P060C
Information saved in
DME
Fault code
2D67 – P060C
Fault text
DME, internal fault: monitoring, processors
45
Fault description
Internal Control Module Main Processor Performance
Condition for fault identification
Test condition:
Internal control-module fault, processor fault in monitor
computer
Terminal condition: Terminal 15 ON
Voltage condition:
Voltage in onboard electrical system >= 10 V
Condition for fault memory entry
immediately
Action in service
Ensure that correct softare and data have been flashprogrammed;
repeat flash-programming as indicated. If
frequency > 3 Replace DME
Fault effect and breakdown warning
Driver information
Warning light:
MIL OFF EML ON CC: Power loss, engine malfunction