Tuesday, June 30, 2020

2010 BMW 128i Convertible (E88) L6-3.0L (N52K) P Code Charts

2010 BMW 128i Convertible (E88) L6-3.0L (N52K) P Code Charts

none

P1075

2A41 – P1075

Information saved in

DME

Fault code

2A41 – P1075

Fault text

Valvetronic, electrical overload protection

Fault description

VVT-Overload Protection (Bank 1)

Condition for fault identification

Test condition:

Electrical overload protection

The engine management monitors the VVT motor’s current

draw. If the monitored current draw exceeds a defined

threshold for several seconds the VVT system is deactivated

(VVT emergency operation mode), and the engine reverts to

throttled operation.

Always active provided that fault codes #10813,#10816,

#10819 are not present.

Terminal condition: none

Voltage condition:

none

Condition for fault memory entry

Warning threshold: 112 掳C DME internal driver circuit

temperature

Deactivation threshold: 126 掳C internal DME driver circuit

temperature

Action in service

1. Check for correct reluctor attachment at VVT sensor.

2. Defective VVT servo motor (for instance, interturn short

205

circuit) Check servo motor and replace as indicated (Clear

fault memory / switch ignition terminals)

3. Check VVT motor wiring harness between VVT motor

and DME for shorts between both VVT motor wires and

vehicle ground.

Fault effect and breakdown warning