Saturday, June 27, 2020

2010 BMW 128i Convertible (E88) L6-3.0L (N52K) P Code Charts

2010 BMW 128i Convertible (E88) L6-3.0L (N52K) P Code Charts

none

P0686

2ACB – P0686

Information saved in

DME

Fault code

2ACB – P0686

Fault text

DME master relay, activation

Fault description

ECM/PCM Power Relay Control Circuit Low

Condition for fault identification

Test condition:

Main relay monitoring

Main relay must have opened.

Terminal condition: First Terminal 15 OFF

(wait until main relay opens)

then Terminal 15 ON

(and leave ON)

Voltage condition:

Voltage in onboard electrical system > 10 V

Condition for fault memory entry

none

Action in service

1 Check wiring

Repair if defective

If wiring is OK proceed

to check component

Fault effect and breakdown warning