Tuesday, June 30, 2020

2010 BMW 128i Convertible (E88) L6-3.0L (N52K) P Code Charts

2010 BMW 128i Convertible (E88) L6-3.0L (N52K) P Code Charts

none

P1062

203

2A44 – P1062

Information saved in

DME

Fault code

2A44 – P1062

Fault text

Valvetronic, power limitation

Fault description

VVT-Limp Home Request Full Stroke Position not Reached

(Bank 1)

Condition for fault identification

Test condition:

1. VVT must be in emergency operation mode (meaning that

no VVT sensor signal is present) and unit travels to upper

travel limit at 30 % pulse-duty factor for VVT motor.

2. The mass induction airflow is employed as an index to

determine whether the maximum VVT stroke has been

reached.

Terminal condition: Terminal 15 ON

Voltage condition:

none

Condition for fault memory entry

after Terminal 15 switch and/or always active if DME is

awake.

Action in service

1. Check and repair the sensor defect using the correct repair

instructions.

2. Check HFM mass airflow signal

2. Check VVT mechnical system (VVT servo motor, VVT

gearset, VVT eccentric shaft,…)

Fault effect and breakdown warning

Driver information

Warning light:

ECE: No warning message. Engine reverts to VVT

emergency backup mode (throttled operation) US: OPEN