2010 BMW 128i Convertible (E88) L6-3.0L (N52K) Manufacturer Code Page 50

2010 BMW 128i Convertible (E88) L6-3.0L (N52K) Manufacturer Code Page 50

2ACB – P0687 (DME)

2ACB – P0687

Information saved in

DME

Fault code

2ACB – P0687

Fault text

DME master relay, activation

Fault description

ECM/PCM Power Relay Control Circuit High

Condition for fault identification

Test condition:

Main relay monitoring

Main relay is deactivated by DME

(8 sec. after Terminal 15 off)

Terminal condition: First Terminal 15 ON then OFF (then

leave OFF)

Voltage condition:

Voltage in onboard electrical system > 10 V

Condition for fault memory entry

none

Action in service

1 Check wiring

Repair if defective

If wiring is OK proceed

to check component

Fault effect and breakdown warning

Driver information

Warning light:

none

Service instruction

none

2ACC

2ACC – P16C5

Information saved in

DME

Fault code

2ACC – P16C5

Fault text

DME master relay, shift delay

Fault description

Main Relay Switching Delay

Condition for fault identification

Test condition:

none

Terminal condition: none

Voltage condition:

none

Condition for fault memory entry