Friday, May 8, 2020

2010 BMW 128i Convertible (E88) L6-3.0L (N52K) Manufacturer Code Page 293

2010 BMW 128i Convertible (E88) L6-3.0L (N52K) Manufacturer Code Page 293

Fault text

Thermal oil-level sensor

Fault description

Engine Oil Level Too Low

Condition for fault identification

Test condition:

Oil level below 5 liters

Terminal condition: Terminal 15 ON

Voltage condition:

Voltage in onboard electrical system > 9 V

Condition for fault memory entry

10 sec.

Action in service

Add 1l engine oil

Fault effect and breakdown warning

Driver information

Warning light:

CC message 28

Service instruction

none

2F10

2F10 – P14C6

Information saved in

DME

Fault code

2F10 – P14C6

Fault text

Radiator blind, bottom

Fault description

Radiator Shutter (Lower) Electrical

Condition for fault identification

Test condition:

1. PKKS must be initialized.

Operation of lower flap:

3 x open and 3 x closed

Or conduct the system test

Terminal condition: Terminal 15 ON

Voltage condition:

Voltage in onboard electrical system > 10 V

Condition for fault memory entry

up to 20 sec.

Action in service

1. Check wire from AKKS PIN 4 to PKKS (connection +)

2. Check ground connection to the PKKS

3. Check retention solenoid (internal short or burned

through)

Fault effect and breakdown warning