Friday, May 8, 2020

2010 BMW 128i Convertible (E88) L6-3.0L (N52K) Manufacturer Code Page 3

2010 BMW 128i Convertible (E88) L6-3.0L (N52K) Manufacturer Code Page 3

Voltage condition:

Voltage in onboard electrical system > 10 V

Condition for fault memory entry

80 ms

Action in service

Check LDM and.. CAN link to LDM control module

Fault effect and breakdown warning

Driver information

Warning light:

none

Service instruction

none

CDAE

CDAE – U113C

Information saved in

DME

Fault code

CDAE – U113C

Fault text

Message (time/date, 2F8)

Fault description

Lost Communication With Time/Date

Condition for fault identification

Test condition:

Instrument cluster recognized

Terminal condition: Terminal 15 ON

Voltage condition:

Voltage in onboard electrical system > 10 V

Condition for fault memory entry

240 sec.

Action in service

Check CAN links between instrument cluster and DME

Fault effect and breakdown warning

Driver information

Warning light:

none

Service instruction

none

CDAF

CDAF – U0137

Information saved in

DME

Fault code

CDAF – U0137

Fault text

Message (status, trailer, 2E4)