Test condition:

EAC sensor must be installed, and the correct data set

(SULEV) must be programmed in the DME

Terminal condition: Terminal 15

Voltage condition:

Voltage in onboard electrical system > 9 V

Condition for fault memory entry

2.5 sec.

Action in service

1.) Check ground wire from DME to EAC sensor

2.) Check positive wire from DME to EAC sensor

3.) Check bus wire from DME to EAC sensor

4.) Replace sensor

Fault effect and breakdown warning

Driver information

Warning light:

MIL comes on after 2nd driving cycle

Service instruction

none

2ADF – P0506 (DME)

2ADF – P0506

Information saved in

DME

Fault code

2ADF – P0506

Fault text

Idle air control, engine speed

Fault description

Idle Air Control System RPM Lower Than Expected

Condition for fault identification

Test condition:

none

Terminal condition: none

Voltage condition:

none

Condition for fault memory entry

none

Action in service

none

Fault effect and breakdown warning