2010 BMW 128i Convertible (E88) L6-3.0L (N52K) Manufacturer Code Page 90
Service instruction
none
(DME) Condition For Fault Memory Entry – None
2A38 – P1030
Information saved in
DME
Fault code
2A38 – P1030
Fault text
Valvetronic, monitoring, sluggish movement
Fault description
VVT-Actuator Monitoring Position Control, Control
Deviation (Bank 1)
Condition for fault identification
Test condition:
none
Terminal condition: none
Voltage condition:
none
Condition for fault memory entry
none
Action in service
none
Fault effect and breakdown warning
Driver information
Warning light:
none
Service instruction
none
(DME) Condition For Fault Memory Entry – 1
2A38 – P1030
Information saved in
DME
Fault code
2A38 – P1030
Fault text
Valvetronic, monitoring, sluggish movement
Fault description
VVT-Actuator Monitoring Position Control, Control
Deviation (Bank 1)
Condition for fault identification
Test condition:
VVT system monitoring for stiction and resistance to
motion.
Always active when no other VVT fault is present.
Terminal condition: Terminal 15 ON
Voltage condition:
Electrical system voltage terminal 87 >10.0 V
Condition for fault memory entry